BD 86 Non Phosphate Detergent

Pre-Startup and Post-Descaling Boiler Cleaning | Removes Oil, Grease, and Process Contaminants Before Treatment Chemistry Goes In | Non-Phosphate Formula for Discharge-Restricted Environments

CI BD86 is the cleaning step that happens before the treatment program starts. New boilers ship with manufacturing oils and greases on internal surfaces. Recently descaled boilers have residual process contaminants left behind after acid cleaning. If those residues stay in the system when the boiler goes into service, they cause foaming, surging, and unstable water levels — operational problems that no corrosion inhibitor or oxygen scavenger can fix because the issue isn’t chemistry, it’s contamination. BD86 is the concentrated alkaline detergent that removes oil films, grease, and residual contaminants so the boiler starts clean and the treatment products applied afterward can actually reach metal surfaces and do their job. Non-phosphate formulation meets discharge requirements in jurisdictions where phosphate limits restrict what goes down the drain after boiler cleaning — a growing regulatory constraint in municipal and institutional settings. Silicates, chelating agents, and non-foaming surfactants emulsify and lift contaminants without generating foam that complicates drainage or interferes with rinse verification. Compatible with all CI boiler treatment products — no neutralization or additional rinsing steps required between BD86 cleaning and the start of the corrosion, scale, or oxygen control program. Every other product in the water treatment line protects the boiler while it runs. BD86 is the one that makes sure it’s clean enough for those products to work when they go in.

$239.00 / 20 L pail
+
Technical Data

Technical Data

Technical Properties

CI BD86

Concentrated alkaline boiler cleaner formulated for pre-startup cleaning and post-descaling cleanup where oil films, grease, and process residues must be removed before treatment chemistry goes into the system. Built to give boiler water treatment a clean starting surface instead of asking corrosion and oxygen-control products to work through contamination they were never designed to solve.

Product Type
Pre-Startup and Post-Descaling Boiler Cleaner

Technology Base
Non-Phosphate Alkaline Detergent Cleaning Chemistry

Primary Function
Remove Oil, Grease, and Residual Process Contaminants Before Treatment Begins

Application Role
Boiler Cleaning Step Before Startup or After Acid Descaling

Performance Focus
Contaminant Removal, Clean Drainage, and Surface Preparation for Follow-On Water Treatment

Operational Mechanism
Silicates, Chelating Agents, and Non-Foaming Surfactants Emulsify and Lift Contaminants Without Foam Interference

Process Target
New Boilers with Manufacturing Oils and Recently Descaled Boilers with Residual Cleaning Contaminants

Operational Benefit
Prevents Foaming, Surging, and Unstable Water Levels Caused by Residual Boiler Contamination

Use Environment
Steam Boiler Plants, Institutional Boiler Rooms, Municipal Facilities, and Discharge-Restricted Maintenance Programs

Program Fit
Pre-Treatment Cleaning Step That Makes the Rest of the Boiler Program Work Properly

Maintenance Value
Reduces Startup Trouble and Helps Avoid Boiler Performance Problems That Treatment Chemistry Cannot Solve After the Fact

Discharge Profile
Non-Phosphate Formula for Jurisdictions with Phosphate Discharge Restrictions

Operational Notes
• This is the cleaning step before the treatment step — if oils and residues stay in the system, no inhibitor or oxygen scavenger can fix the operational instability they create
• Best used on new boilers carrying manufacturing oils and on recently descaled boilers still contaminated from the cleaning process
• Non-foaming surfactant package matters because it cleans without creating drainage and rinse-verification headaches
• Strong fit where discharge restrictions make phosphate-containing boiler cleaners harder to justify or use
• Compatible with all CI boiler treatment products, so operators can move from cleaning into treatment without awkward neutralization or extra transition chemistry
• Every other product in the line protects the boiler while it runs — BD86 is the one that makes sure the boiler is clean enough for those products to reach the metal and do their job

Practical Fit
CI BD86 is the boiler cleaning product for operators who understand that treatment chemistry is not magic. It belongs at the front of the program — before startup and after descaling — where the real job is to strip out contamination that would otherwise cause foaming, surging, unstable water levels, and poor treatment performance from day one.

This block is built directly from the positioning you provided: a non-phosphate alkaline boiler cleaner for pre-startup and post-descaling use, designed to remove manufacturing oils, grease films, and residual process contaminants before the operating treatment program begins. It preserves the line architecture by defining BD86 as the preparatory cleaning product, distinct from oxygen scavengers like SP50 and OS100 and from inhibitor treatments like No. 20, No. 25, No. 34, No. 38, and PD90, none of which are meant to solve contamination left behind before the boiler goes into service.
Documents

Related Documents