CI OS100 Catalyzed Oxygen Scavenger

Steam Boilers and High-Pressure Systems | Eliminates Dissolved Oxygen Faster Than Standard Sulfite | Catalyzed Chemistry That Reacts at Low Temperatures and During System Upsets

CI OS100 is the catalyzed oxygen scavenger for steam boiler systems where standard sulfite isn’t fast enough. Its sodium sulfite base is enhanced with a proprietary catalyst that accelerates the oxygen-sulfite reaction at lower feedwater temperatures and during the load swings, startups, and fluctuating conditions where uncatalyzed scavengers lag behind and leave tube walls exposed. Where CI SP50 is the standard liquid sulfite scavenger for steady-state steam systems, OS100 is the upgrade for operations where feedwater conditions are less predictable and the operator needs oxygen removed on contact, not minutes later. Dosed into the makeup or feedwater line, it reacts immediately upon contact with dissolved oxygen and maintains consistent sulfite residual in the 50–100 ppm range when monitored properly — neutralizing oxygen before it reaches critical boiler surfaces. Liquid format feeds cleanly without the clumping, undissolved solids, or feed line plugging associated with dry sulfite products. By keeping oxygen out of the boiler water faster and more reliably, OS100 reduces the pitting corrosion, tube failures, and heat transfer losses that drive unplanned shutdowns and pressure-part replacements. Compatible with other CI boiler treatment chemicals and standard automated or manual feed systems. Same job as SP50 — but faster, more responsive, and built for systems where conditions don’t stay steady long enough for standard sulfite to keep up.

$329.00 / 20 L pail
+
Technical Data

Technical Data

Technical Properties

CI OS100 Catalyzed Oxygen Scavenger

Catalyzed liquid sodium sulfite oxygen scavenger formulated for steam boilers and higher-pressure systems where standard sulfite is too slow to keep up. Built for operators who need dissolved oxygen removed quickly during startups, load swings, colder feedwater conditions, and other unstable operating periods where oxygen attack can outrun an ordinary scavenger program.

Product Type
Catalyzed Liquid Oxygen Scavenger

Technology Base
Catalyzed Sodium Sulfite Oxygen-Removal Chemistry

Primary Function
Eliminate Dissolved Oxygen Faster Than Standard Sulfite Programs

Application Role
Rapid Oxygen Control for Steam Boiler Feedwater Under Variable Conditions

Performance Focus
Fast Reaction Speed, Low-Temperature Response, and Upset-Condition Oxygen Scavenging

Operational Mechanism
Catalyst Accelerates the Sulfite-Oxygen Reaction So Oxygen Is Neutralized Earlier in the Feedwater Cycle

Process Target
Steam Boiler Feedwater, Makeup Water Lines, and Systems with High Condensate Return

Operational Benefit
Provides Faster, More Responsive Oxygen Removal When Standard Sulfite Cannot React Quickly Enough

Use Environment
Steam Boilers, Manufacturing Plants, Food Processing Operations, Power Generation, and Institutional Heating Facilities

Program Fit
Upgrade Oxygen-Scavenger Option for Steam Systems with Less Predictable Feedwater Conditions

Maintenance Value
Helps Prevent Pitting, Tube Failures, Heat-Transfer Loss, and Pressure-Part Damage During Real-World Boiler Upsets

Feed Compatibility
Liquid Feed Compatible · Automated or Manual Dosing · No Powder Clumping or Feed-Line Plugging

Operational Notes
• This is the faster oxygen-scavenger option in the line — same fundamental job as SP50, but designed for systems where standard sulfite response is not fast enough
• Best used during startups, load swings, colder feedwater conditions, and other upset periods where oxygen must be removed on contact, not later in the cycle
• Particularly strong fit for systems with high condensate return, where oxygen ingress through the return side creates ongoing corrosion risk
• Liquid format eliminates the feed problems associated with dry sulfite products — no clumping, no undissolved solids, and no plugging in chemical feed lines
• Maintaining sulfite residual in the 50–100 ppm range gives operators a practical control target for keeping oxygen removal active
• Same job as SP50, different speed profile — this is the responsive scavenger for steam systems that do not stay steady long enough for ordinary sulfite to keep up

Practical Fit
CI OS100 is the catalyzed oxygen scavenger for steam systems where standard sulfite is too slow for the way the plant actually runs. It belongs where feedwater conditions swing, startups are hard, condensate return matters, and the operator needs oxygen neutralized fast enough to protect the metal before the upset has already done the damage.

This block is built directly from the positioning you provided: a catalyzed sodium sulfite oxygen scavenger for steam boilers and higher-pressure systems, designed to react faster than standard sulfite at lower feedwater temperatures and during startups, load swings, and unstable operating conditions. It preserves the product architecture you established by positioning CI SP50 as the standard liquid sulfite scavenger for steadier steam systems, while CI OS100 is the faster, more responsive oxygen-control option when ordinary sulfite cannot keep up.