CI No. 49 – Filming Steam Boiler Compound

Full Steam-System Corrosion Protection from Boiler to Condensate Return

CI No. 49 is the upgraded steam-system corrosion inhibitor for operators who need more than simple acid neutralization in the condensate return. Where No. 45 neutralizes carbonic acid, No. 49 adds a second line of defense: filming amines that lay down a hydrophobic barrier on internal metal surfaces. That means two protection mechanisms working together — neutralizing amines handle the acid chemistry, while filming amines help keep corrosive condensate from contacting the metal in the first place.

This makes No. 49 the stronger choice in steam systems with more aggressive condensate conditions, higher purity requirements, or a history of return-line pitting, trap failures, and premature metal loss that neutralization alone has not fully solved. Instead of protecting only through pH correction, it protects through both chemical neutralization and physical surface shielding across the steam-condensate cycle.

CI No. 49 is the condensate-side upgrade for operators who want fuller downstream protection and visible confirmation that treatment is reaching the system. In practical terms, it helps extend the life of steam traps, heat exchangers, return piping, and other condensate-handling components while reducing the kind of hidden metal loss that turns a steam system into a recurring repair file.

$225.00 / 20 L pail
+
Technical Data

Technical Data

Technical Properties

CI No. 49 Filming Steam Boiler Compound

Dual-mechanism steam treatment formulated for full steam-system protection from boiler through condensate return. Built for operators who need more than simple acid neutralization on the condensate side and want both chemical neutralization and physical surface shielding working together across the steam-condensate cycle.

Product Type
Filming Steam Boiler and Condensate Corrosion Inhibitor

Technology Base
Dual Neutralizing Amine and Film-Forming Amine Chemistry

Primary Function
Protect Steam and Condensate Systems Through Acid Neutralization and Surface Film Shielding

Application Role
Full Steam-System Corrosion Protection from Boiler Through Condensate Return

Performance Focus
Condensate Acid Neutralization, Hydrophobic Surface Protection, and Downstream Steam-System Defense

Operational Mechanism
Neutralizing Amines Handle Carbonic Acid While Filming Amines Lay Down a Water-Repelling Barrier on Internal Metal Surfaces

Process Target
Steam Traps, Heat Exchangers, Return Piping, Condensate Lines, and Boiler Internals

Operational Benefit
Adds a Physical Barrier Where Standard Condensate Neutralization Alone Has Not Been Enough

Use Environment
Steam Boiler Plants, Condensate Recovery Systems, High-Purity Steam Operations, and Facilities with Aggressive Return-Side Corrosion History

Program Fit
Condensate-Side Upgrade When Neutralization Alone Is Not Enough

Maintenance Value
Helps Extend the Life of Traps, Return Piping, Heat Exchangers, and Condensate Hardware in Systems with Repeat Downstream Metal Loss

Verification Aid
Includes Fluorescein Tracer Dye for Visual Confirmation of Treatment Presence

Operational Notes
• This is the condensate-side upgrade for systems where No. 45 style neutralization is directionally right but not enough by itself
• Neutralizing amines handle the acid chemistry; filming amines add a hydrophobic barrier so corrosive condensate is less able to contact the metal directly
• Best used where condensate return piping, traps, and exchangers have a history of pitting, metal loss, or premature failure under aggressive return-side conditions
• Strong fit in higher-purity steam systems and facilities that need broader downstream corrosion protection than pH correction alone can provide
• Fluorescein tracer gives operators a fast visual check that the treatment is present across changing loads and system conditions
• No. 45 remains the standard neutralizing option; No. 49 is the stronger choice when the condensate side needs both chemical and physical lines of defense

Practical Fit
CI No. 49 is the condensate-side upgrade for steam systems that keep corroding even after acid neutralization has been addressed. It belongs where operators need more than pH correction — where the return side needs both neutralizing chemistry and a physical protective film to keep condensate from eating the metal underneath it.

This block is built from the revised positioning you approved: CI No. 49 as the upgraded condensate-side steam treatment that goes beyond No. 45 by combining neutralizing amines with film-forming amines. The product is therefore positioned here as the stronger downstream-protection option for steam and condensate systems where neutralization alone has not been enough to stop pitting, trap failures, and return-side metal loss.