CI360™ · WW · 6 stages · one rack cycle · 3 machine programs

Warewash programs do not fail on chemistry. They fail on drift — a final-rinse temperature nobody has measured this month, a sanitizer pump that quietly lost calibration, a delime interval set by habit instead of water hardness.

WarewashStart with the temperature the machine is actually delivering.

Section 01 · Program overview

One rack cycle, six stages — and every product owns exactly one of them

Six stages. One rack cycle. Three machine programs.

CI360™ is a task-based program, not a product shelf. Warewash runs as a closed cycle: presoak, wash, rinse, sanitize, verify, maintain — and back to the next rack. Each stage has one job and one product lane. The program fails when the lanes blur: two detergents in one machine, a hand-sink detergent poured into a machine tank, chemical sanitizer stacked on top of a machine that already sanitizes with heat, or a delime cycle that only happens when scale is visible on the arms.

The controlling variable is temperature. What the final rinse actually delivers decides the detergent, the rinse logic, whether a chemical sanitizer is required at all, and how tight the deliming interval has to be. Every other decision on this page follows from that one measurement — and it has to be a measurement, not an assumption.

Six stages · click a segment on the dial or a stage in the list
Selected stageOther stagesDashed outer arc = the rack cycle repeatingRed inner arc = the rewash loop this program exists to eliminate
Food ServiceCommercial Sanitation= catalogue section of a linked product
S1PresoakSoil off the wareS2WashOne detergentS3RinseSheet, not beadS4SanitizeHeat or verified ppmS5VerifyRead the exit rackS6MaintainDelime on intervalCI360WAREWASH
The operating route
1MeasureFinal rinse temperature at the rack, before anything else
2AssignOne product to each stage — no duplicates
3SetFeed rates, dwell times, and the delime interval
4VerifyTemperature, ppm, sheeting, rewash rate — every shift
Failure mode 01Temperature assumed, not measuredA machine rated for high-temp operation is not a machine holding 180 °F at the rack. Boosters drift, elements scale over, and nobody notices until an inspection does. Every other decision on the line is downstream of this number.
Failure mode 02Two detergents in one machineRunning liquid and granular together “to be safe” doubles alkalinity, etches glassware, and shows up downstream as a rinse problem. One detergent per machine, matched to the temperature and the water.
Failure mode 03Manual chemistry in machine dosingHand-sink detergents are high-suds by design. One pour into a machine tank foams the wash pump dry and ends the shift. The manual line runs beside the machine, never into it.
Failure mode 04Sanitizer ppm unverifiedOn low-temp and bar-glass machines the sanitizer is the kill step, and it is a health-code number rather than a preference. Pump calibration drifts, eductors dilute, drums run empty, and test strips expire. Verify with fresh strips, every shift.
Failure mode 05Deliming by sightBy the time scale is visible on the arms it is already restricting flow, choking jets, and insulating elements. The interval is set by water hardness, and it is the first thing to check when film and spotting appear.
The one-product-per-stage rule
Six stages, one system
  • Presoak releases protein before the rack, so the machine is not over-dosed to compensate.
  • One machine detergent carries the wash — liquid, granular, or non-chlorinated glass.
  • Rinse additive controls hard-water residue and produces sheeting, not droplets.
  • The sanitize step is either heat or verified chemistry — never both on the same rack.
  • Verification is a stage with its own outputs: temperature, ppm, sheeting, rewash rate.
  • Deliming runs off the daily line, on an interval set by water hardness.
Planning mistakes this program avoids
  • Raising detergent feed to chase a problem that belongs in the presoak sink.
  • Adding chemical sanitizer to a high-temp machine that is already sanitizing thermally.
  • Running chlorine chemistry through a bar glass program and calling the result a rinse problem.
  • Changing products before verifying temperature, feed rate, and delime interval.
  • Treating the three-compartment sink and the machine as one chemistry system.
S1PresoakSoil off the wareS2WashOne detergentS3RinseSheet, not beadS4SanitizeHeat or verified ppmS5VerifyRead the exit rackS6MaintainDelime on interval360
Section 02 · Stage S1 · Presoak

Presoak

Protein released before the rack, so the wash stage is not asked to solve it alone.

ResultFewer rewashes, less soil into the tank, no over-dosing to compensate

“The machine should not be asked to solve a problem that belongs in the presoak sink. Raising detergent feed to chase protein soil etches glass and films ware.”

Presoak is a staged step, not a standing bucket. It earns its place where protein soil recurs — egg, dairy, meat, and baked-on organic residue on flatware. Enzymes need both temperature and time: hold the bath between 37–50 °C, because colder water slows the protease and hotter water denatures it. Then rinse the ware before racking, or presoak residue carries into the wash tank and foams the pump.

The presoak logic
1Scrape firstGross soil leaves at the table, not in the bath
2Dose to label1:20 with the 20X concentrate · not by eye
3Hold the band37–50 °C · too hot kills the enzyme
4Dwell10 minutes minimum · time does the work
5Rinse before rackingPresoak residue foams the wash tank
The chemistry cabinet · colour dot = the catalogue section each product lives in · tap a name to open its product page
Protein flatware presoak20X protease concentrate for egg, dairy, meat, and baked-on protein. Safe on silver and stainless.
Soil-specific presoak lanesTannin, silver, plastic staining, and mixed loads are separate problems with separate chemistry — specify the lane with your CI representative.
Tannin on china and melamine — chlorinated stain presoak for tea and coffee cup staining.
Silver flatware — non-chlorinated presoak where tarnish risk rules out chlorine chemistry.
Plastic and melamine staining — oxidative lift for tomato, curry, and turmeric.
General mixed loads — where no enzyme, silver-safe, or stain-lift chemistry is required.
Stage-to-product map · sheet WW-01
SheetWW-01StageS1 · PresoakStandardProtein released · temperature held · rinsed before rackingProducts1
SCRAP TABLE · UNDERCOUNTERTO THE RACKSoiled ware · scrape firstSCRAP1:20 · enzyme presoak37–50 °Chold the band≥ 10 MINRinse before rackingRacked flatware12345
Task / condition · best-fit productsWhy it belongs · operator note
1Scrape and scrap before the bathGross soil belongs in the scrap opening, not in presoak chemistry.A presoak bath loaded with food debris stops working within an hour. Scraping is the cheapest step in the dishroom and the one most often skipped when the line backs up.
2Protein soil on flatwareCI WareWash Enzyme PreSoak20X concentrated protease presoak for egg, dairy, meat, and baked-on protein; safe on silver and stainless steel.Stage it where protein soil recurs, not everywhere by default. Where the soil does not justify it, the stage is skipped and the machine carries the load.
3Bath temperature37–50 °C is the working band for the protease.Below the band the enzyme is slow; above it the enzyme is destroyed and you are soaking in warm water. Put a thermometer in the bath and treat the band as a set-point, not a preference.
4Dwell timeTen minutes minimum. Time is what the enzyme uses.Shortening dwell to keep the line moving is what pushes protein soil into the wash tank. If the bath cannot hold ten minutes, the bath is undersized for the volume.
5Rinse before rackingPresoaked ware carries presoak chemistry into the machine.This is the single most common cause of foam in a wash tank that is otherwise correctly dosed. Rinse the flatware, then rack it.
The presoak decision

Presoak earns its place — or it does not run.

The machine can carry it when…
  • Soil is mixed food debris rather than baked-on protein.
  • Flatware reaches the machine within a shift, not the next morning.
  • First-pass results are clean and the rewash rate is flat.
  • The wash stage is correctly dosed and verified.
Protein loadsoil type · vs · rewash rate
Stage it when…
  • Egg, dairy, and meat residue is a daily recurring soil.
  • Flatware sits before it reaches the machine.
  • Flatware comes off the rack filmed while plates come off clean.
  • Detergent feed is being raised to compensate for one soil type.

Scrape → soak → rinse → rack.

The presoak stage exists to change what enters the wash tank. Every gram of protein released in the sink is soil the machine does not have to carry, alkalinity it does not have to spend, and water it does not have to change early. Where the stage is running correctly, the wash tank stays cleaner for longer and the rewash rate drops without a single change to the detergent.

Do not raise detergent to chase protein

Over-dosing machine detergent to solve a presoak problem etches glassware, films ware, and raises chemical cost on every rack in the building to fix a soil that appears on one. Fix the stage that owns the problem.

Signs this stage is missing

Flatware returns for a rewash while plates and glassware come off clean. Protein film appears on tines and spoon bowls. Detergent consumption is climbing with no change in cover count. Operators describe the detergent as “not working like it used to.”

Signs this stage is mis-run

Foam in the wash tank shortly after a presoak batch is racked — ware was not rinsed. A bath that is hot to the touch — the protease is denatured and the soak is doing nothing. A bath left standing all shift, loaded with debris, doing less than plain water.

S1PresoakSoil off the wareS2WashOne detergentS3RinseSheet, not beadS4SanitizeHeat or verified ppmS5VerifyRead the exit rackS6MaintainDelime on interval360
Section 03 · Stage S2 · Wash

Wash

One detergent per machine, matched to the final-rinse temperature and the water it runs on.

ResultFirst-pass cleanliness, controlled foam, no etched glass

“One detergent per machine. Two is not insurance — it is double alkalinity, etched glassware, and a rinse problem you will spend a week chasing.”

The wash stage is where soil is removed, and it is the only stage where the choice of product is genuinely a choice. Liquid alkaline covers most high-temp and many low-temp machines and holds performance in hard water. Phosphate-free granular is the lane where discharge is restricted or a dry feed suits the site. Non-chlorinated glass chemistry is a separate lane entirely, because chlorine is what puts odour and film on beverage glass.

Set the feed at 2–4 mL/L through the dispenser, then verify low foam and first-pass cleanliness before touching the controller again. If ware is coming out clean but not clear, the answer is almost always rinse aid or scale — not more detergent.

The wash logic
1Confirm the machineHigh-temp, low-temp, or bar glass — measured
2Set the feed2–4 mL/L by dispenser · not by eye
3Check the foamLow foam is a specification, not a preference
4Read the first passClean on the first rack, or the dose is wrong
5Adjust to soil and hardnessWithin spec · then leave it alone
The chemistry cabinet
The workhorse — liquid alkalineHigh-alkaline liquid with built-in sequestrants. Runs high-temp and low-temp machines, and holds up where the water is hard.
CI Machine Dishwash L-TypeLiquid machine detergent
Phosphate-free granularActive-oxygen granular with built-in water softeners and protein removers. The lane for discharge-restricted or dry-feed sites.
CI Machine Dishwash P-TypeGranular · active oxygen
Bar and glass — non-chlorinatedGlass clarity is the whole job. Chlorine is what drives odour, film, and flat beer heads.
CI Bar Glass CleanerNon-chlorinated low-foam
Stage-to-product map · sheet WW-02
SheetWW-02StageS2 · WashStandardOne detergent · low foam · clean on the first passProducts3
DIRTY INCLEAN OUTPREWASHWASH TANKScrap screenAUTO-FEED2–4 mL/Lset to soil + hardnessLOW FOAM ONLY · NO MANUAL DETERGENT IN THE TANK12345
Task / condition · best-fit productsWhy it belongs · operator note
1Scrap screens and wash armsChemistry cannot reach ware that the spray pattern is not hitting.Clogged jets and loaded screens read exactly like an under-dosed detergent. Clear them before you touch the feed rate — it is a two-minute check that resolves a large share of “soil remaining” calls.
2High-volume machine wash · hard waterCI Machine Dishwash L-TypeConcentrated high-alkaline liquid with sequestering agents for grease, baked-on protein, and hard-water minerals; runs across high- and low-temp systems.This is the default lane. Hard water and heavy food soil are the conditions it was built for, and one liquid covering both machine types keeps the dishroom on a single SKU.
3Phosphate-restricted or dry-feed sitesCI Machine Dishwash P-TypePhosphate-free granular with an active-oxygen system, built-in water softeners, protein removers, and free-rinsing wetting agents.Choose it for the discharge requirement or the dispenser format, not for performance ranking. It is a parallel lane to the liquid, not a step above or below it.
4Bar, glass, and bottle washersCI Bar Glass CleanerNon-chlorinated, low-foaming liquid for automatic glass and bottle washers — cuts beverage residue, lipstick, and protein film without chlorine.Do not substitute a dish detergent here. Chlorine residue transfers taste and smell to the next pour and kills head retention on beer glass.
5Detergent feed rateCI Machine Dishwash L-TypeCI Bar Glass Cleaner2–4 mL/L through the dispenser, adjusted to soil load and water hardness.Set it, verify it, and log it. A feed rate adjusted by eye every time someone is unhappy with a rack is the fastest route to both etched glass and unexplained chemical spend.
6Foam in the wash tankMachine detergents are low-foam by specification.Foam means either manual chemistry has entered the tank or presoaked ware was racked unrinsed. Drain, refill, and find the source — do not dose a defoamer into a warewash tank as a routine fix.
The wash decision

Liquid or granular is a site decision, not a performance one.

Liquid is right when…
  • Water is hard and sequestration is doing real work.
  • The site already runs liquid dispensing equipment.
  • One detergent has to cover both a high-temp and a low-temp machine.
  • Soil load is heavy and variable across the day.
Format follows the sitedischarge rules · dispenser · water
Granular is right when…
  • Phosphate discharge is restricted by the receiving system.
  • A dry feed suits the dispenser and the storage.
  • Active-oxygen stain removal is wanted on china and melamine.
  • Built-in softeners are preferred over separate treatment.

Clean, but not clear, is a rinse problem.

The most common misread in a dishroom is treating a clarity problem as a detergent problem. Ware that comes off the rack clean but spotted, filmed, or hazy is telling you about hard-water residue, rinse-aid feed, or scale — all downstream of the wash stage. Raising detergent in response makes the glass worse and the invoice larger.

One detergent per machine

Running a liquid and a granular together doubles alkalinity in the tank, etches glassware permanently, and produces a film that no rinse additive can correct. If a second detergent is on the shelf for a second machine, label the dispensers and keep them apart.

S1PresoakSoil off the wareS2WashOne detergentS3RinseSheet, not beadS4SanitizeHeat or verified ppmS5VerifyRead the exit rackS6MaintainDelime on interval360
Section 04 · Stages S3–S4 · Rinse & sanitize

Rinse & Sanitize

Sheeting rather than droplets — and a kill step you can put a number on.

ResultSpot-free ware and a sanitize step that can be proven at the rack

“Sheeting is not cosmetic. Water that beads is water still carrying hardness onto the ware — and it will dry there.”

The final rinse does two jobs on the same pass. The rinse additive neutralizes hard-water residue and drops surface tension so water leaves the ware as one unbroken film. The sanitize step is either heat or chemistry, decided entirely by what the machine actually delivers: thermal on a machine holding 180–195 °F at the rack, verified iodine or chlorine on a low-temp machine, and iodine at 12 ppm on bar glass.

Where a machine has two rinse pumps, keep rinse aid and sanitizer in separate lanes. Where it has one, use a combined feed only if both the controller and the product are designed for it. And never dilute iodine with hot water at the eductor — it strips the residual you are trying to verify.

The rinse and sanitize logic
1Measure at the rackThe gauge is not the rack · use a strip or probe
2Set rinse to sheetingOne unbroken film · 8–15 s to dry
3Decide the kill stepHeat above 180 °F · chemistry below it
4Verify ppmFresh strips · current lot · every shift
5Log itAn unlogged reading is not a verification
The chemistry cabinet
Final rinse — sheeting and scale controlNon-foaming rinse additive with balanced wetting agents and a mild acid that neutralizes hard-water residue on ware and machine internals.
Chemical sanitize — iodineLow-foaming iodine sanitizer and rinse aid for bar glass washers and low-temp machines. 16% iodine complex with 8.8% lactic acid.
CI SanitrolIodine sanitizer
Stage-to-product map · sheet WW-03
SheetWW-03StageS3–S4 · Rinse & sanitizeStandardFull sheeting · verified kill step · logged every shiftProducts2
FINAL RINSE ZONEREAD AT THE RACKBOOSTER180+180–195 °F · 82–91 °Cmeasured at the rack, not the gauge0.7 mL/L → 12 ppmbar glass iodine targetno hot water at the eductorSHEETING8–15 s · unbroken filmBEADINGcheck rinse feed12345
Task / condition · best-fit productsWhy it belongs · operator note
1Final-rinse temperature180–195 °F (82–91 °C) on a high-temp machine, measured at the rack.Heat sanitizing only happens at temperature. A clean-looking rack is not proof, and the panel gauge reads the manifold rather than the ware. Use a dishwasher-safe thermometer or thermal strip.
2Rinse additive feedCI Sprinse Rinse AdditiveNon-foaming rinse additive with wetting agents and mild acid for rapid sheeting and hard-water residue control on ware and machine internals.Water should leave the ware as one unbroken film and dry in 8–15 seconds. Standing droplets mean the rinse feed needs adjusting — before anyone touches the detergent.
3Thermal sanitizing · high-temp machinesThe heat is the kill step. No chemical sanitizer belongs in the cycle.Adding sanitizer on top of a machine that is already sanitizing thermally buys nothing, costs money, and can taint glassware. If the machine cannot hold temperature, move it to the chemical lane and re-verify — do not run both.
4Chemical sanitizing · low-temp machinesCI SanitrolVerified iodine at the final rinse where the machine runs around 160 °F (71 °C).This is the kill step and a health-code number, not a preference. Confirm with fresh strips from the current lot at least once per shift, and log the reading.
5Bar glass · iodine at 12 ppmCI SanitrolCI Bar Glass Cleaner0.7 mL/L to a 12 ppm iodine target in the final rinse, paired with non-chlorinated wash chemistry.Do not dilute iodine with hot water at the eductor. Hot-water dilution is the most common reason a correctly set pump still reads short on the strip.
6Odour or aftertaste on beverage glassCI Bar Glass CleanerCI SanitrolChlorine contact anywhere in the glass program transfers taste and smell to the next pour.Move the whole program to non-chlorinated wash chemistry and iodine, then verify ppm and eliminate hot-water dilution. Flat beer heads and “wine tastes off” are the same fault reported two ways.
The sanitize decision

The machine decides the kill step. Not the preference of the site.

Thermal, when…
  • The final rinse holds 180–195 °F measured at the rack.
  • The booster recovers between racks at full production rate.
  • Descaling is on interval and elements are clear.
  • Temperature is logged, not assumed.
Kill stepmeasured °F · vs · verified ppm
Chemical, when…
  • The machine runs low-temp at around 160 °F.
  • It is a bar or bottle glass washer at around 140 °F.
  • The booster cannot hold temperature at production rate.
  • Local requirement specifies a chemical residual.

Check first · film or spotting.

1 · Verify temperatureFinal rinse, at the rack2 · Verify the feedsRinse aid, then sanitizer ppm3 · Delime the machineScale reads as chemistry4 · Change chemistryLast move, not the firstDO NOT CHANGE PRODUCT UNTIL 1–3 ARE RULED OUTCHECK FIRST · FILM OR SPOTTINGLAST RESORT
Two pumps, two lanes

Where the machine has separate rinse and sanitizer pumps, keep the products separate. Where there is a single pump, a combined feed is only acceptable if both the controller and the product are designed for it. Improvising here produces a rinse that under-delivers on both jobs.

S1PresoakSoil off the wareS2WashOne detergentS3RinseSheet, not beadS4SanitizeHeat or verified ppmS5VerifyRead the exit rackS6MaintainDelime on interval360
Section 05 · Stages S5–S6 · Verify & maintain

Verify & Maintain

The exit read, the shift log, the delime interval — and the manual line that runs beside the machine.

ResultDrift caught at the rack instead of at the inspection

“Most warewash failures are drift, not chemistry. Verify temperature, feed, and delime interval before you change a single product.”

Verification is a stage, not an afterthought. Four readings — final-rinse temperature, sanitizer ppm, sheeting behaviour, and rewash rate — catch nearly all warewash drift before it reaches a customer or an inspector. None of them takes more than a minute, and all four belong on a shift log rather than in someone’s memory.

Deliming is the maintenance stage that keeps the rest honest. Missed delime cycles are the most common cause of film, cloudy glass, weak spray pattern, and a booster that no longer reaches temperature. Set the interval by measured water hardness and run it off the daily line — never during service, and never in the same cycle as detergent or sanitizer. The manual three-compartment line runs beside all of this on its own chemistry, and that chemistry never enters machine dosing.

The verification logic
1Read the exit rackDry, no spots, no film, in 8–15 seconds
2Log the numbers°F and ppm, every shift, on paper or in the system
3Track the rewash rateThe one number that summarises the whole program
4Delime on intervalSet by water hardness, not by what you can see
5Keep the lanes apartManual sink chemistry never enters the machine
The chemistry cabinet
Scale control · scheduled PMNon-foaming acid descaler for calcium, lime, and mineral scale in dish machines, glass washers, and water-fed equipment.
The manual line — pot, pan, and three-sinkHigh-suds by design and correct for hand work. None of these products ever goes into a machine tank.
Surfaces outside the machineQuat disinfectant for food-contact surfaces and general kitchen sanitizing. Not a machine rinse sanitizer.
CI OstroSan QuatQuat · DIN 02465116
Stage-to-product map · sheet WW-04
SheetWW-04StageS5–S6 · Verify & maintainStandardNumbers logged · scale controlled · lanes kept apartProducts5
EXIT · VERIFICATION POINTOFF THE MACHINE LINEDry · no filmSHIFT LOG°F · ppm · sheeting · rewashDELIME CYCLEinterval set by water hardnessWASHRINSESANManual line · separate chemistrynever dosed into the machine12345
Task / condition · best-fit productsWhy it belongs · operator note
1The exit readDry ware with no standing droplets in 8–15 seconds is the program working.Spots, film, or wet stacks each point back to a specific stage. Read the rack every shift and treat what you see as a diagnostic, not a complaint.
2The shift logFinal-rinse temperature, sanitizer ppm, sheeting, and rewash rate.A program that lives in one supervisor’s head resets every time that person moves on. Four numbers on a wall sheet survive staff turnover; a verbal standard does not.
3Scale control and delimingCI Scalzoff Acid DescalerNon-foaming acid descaler that dissolves calcium, lime, and magnesium scale in dish machines, glass washers, and other water-fed equipment.Set the interval by measured hardness. Run it off the daily line, never during service, and never in the same cycle as detergent or sanitizer.
4Pot, pan, and three-sink workCI ZIP Pot & Pan DishWashCI Platinum Dish DetergentCI Soft & GentleHigh-suds lemon liquid for baked-on cookware; a 2X neutral-pH concentrate for high-volume sinks; a food-plant manual detergent effective across all water conditions.Pick one as the site standard for the sink and keep it there. These are high-suds by design — one pour into a machine tank foams the wash pump dry.
5Food-contact surfaces outside the machineCI OstroSan QuatQuaternary ammonium disinfectant and deodorizer for food-contact surfaces and general kitchen sanitizing, DIN 02465116.Surface sanitizing and machine rinse sanitizing are separate systems with separate products. Do not substitute one for the other in either direction.
6Rewash rateRacks that need a second pass, tracked as a number.Rewash rate is the single figure that summarises presoak, wash, rinse, and sanitize together. Any upward movement is a signal to check the four readings before anyone reaches for a different product.
The maintenance decision

The delime interval is set by the water, not the calendar.

A longer interval is right when…
  • Incoming water is soft or softened at the building.
  • Rinse additive feed is verified and sheeting is holding.
  • Spray arms and jets are clear on inspection.
  • Booster recovery is holding at full production rate.
Delime intervalmeasured hardness · not habit
A shorter interval is right when…
  • Incoming water is hard and untreated.
  • Film returns within days of a delime cycle.
  • Spray pattern weakens between scheduled cycles.
  • The booster is slower to recover than it was.

Read → log → correct → delime.

Verification exists so that corrective action is aimed at the right stage. A dishroom that logs four numbers can tell the difference between an under-dosed tank, a drifting sanitizer pump, a rinse feed that needs resetting after a delime, and a machine that simply needs descaling. A dishroom that logs nothing can only change products and hope.

Reset the rinse feed after every delime

Descaling changes the surface condition of the machine and, on many systems, the effective rinse feed rate. Spotting that appears immediately after a delime cycle is almost always a rinse-aid feed that needs re-setting — not evidence that the descale was wrong.

Keep the lanes separate

Machine detergent, manual sink detergent, machine rinse sanitizer, and surface disinfectant are four systems, not four options. Every warewash program that collapses does so by letting one of them wander into another’s job.

Descale is not a service-hours job

Deliming never runs during service and never shares a cycle with detergent or sanitizer. Schedule it, log it, and tie the interval back to the actual water — not to the last time somebody noticed scale on the arms.

Section 06 · Machine deployment

One system, three machine programs — what changes is the kill step, not the logic

The stage sequence stays fixed. Temperature decides the sanitize lane and the chemistry that supports it.

CI360 warewash scales from a single undercounter glass washer to a rack conveyor in an institutional kitchen on the same six stages. What moves between deployments is the final-rinse temperature and therefore the sanitize step — thermal above 180 °F, verified chemistry below it, and iodine at a tightly controlled 12 ppm on bar glass.

High-Temperature Machine
Rack conveyor or door type · ≥ 180 °F / 82 °C final rinse

Wash

Machine Dishwash L-Type at 2–4 mL/L, or P-Type where a phosphate-free granular suits the site.

Rinse

Sprinse Rinse Additive, set to full sheeting with no droplets or breaks on the ware.

Sanitize

Thermal. No chemical sanitizer in the cycle where the final rinse genuinely holds temperature.

PM

Scalzoff on a delime interval set to local water hardness.

Low-Temperature Machine
Chemical sanitizing · around 160 °F / 71 °C final rinse

Wash

Machine Dishwash L-Type where approved for the machine and the water.

Rinse

Sprinse Rinse Additive for sheeting and hard-water residue control.

Sanitize

Sanitrol iodine at the final rinse, verified with fresh test strips every shift. This is the kill step.

Guardrail

Two rinse pumps: keep rinse aid and sanitizer separate. One pump: combined feed only where the controller and product allow it.

Bar Glass Washer
Non-chlorinated wash · around 140 °F / 60 °C · iodine final rinse

Wash

Bar Glass Cleaner at 2–4 mL/L — non-chlorinated, for film-free glass with no odour transfer.

Rinse

Sprinse Rinse Additive for clarity and sheeting; head retention on beer glass depends on it.

Sanitize

Sanitrol at 0.7 mL/L to a 12 ppm iodine target. Do not dilute with hot water at the eductor.

Avoid

Chlorine anywhere in the glass program. It is what drives odour, film, and spotting on glassware.

Planned control cycle · twelve-month view
M1M2M3M4M5M6M7M8M9M10M11M12EVERY SHIFTTemperature + ppmDAILYScreens, arms, tankMONTHLYFeed + titrationINTERVALDelimeDELIMEDELIMEDELIMEDELIMEHARD WATER COMPRESSES THE DELIME INTERVAL · IT DOES NOT CHANGE THE SEQUENCE
At-a-glance matrix · what problem are you actually solving?
Condition in the dishroomWhat you are actually looking atStageWhere it belongs in the cycleFirst moveDo this before anything elseProductsEscalate only if…
S1Protein film on flatwarePresoakStage an enzyme presoak before the rack.CI WareWash Enzyme PreSoakFilm persists after a correct soak — check dwell and bath temperature.
S2Food soil remaining after the cycleWashClear screens and arms, then confirm feed within spec.CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoakSoil remains at correct feed — check mechanical action and rack loading.
S2Phosphate discharge restrictedWashMove to the phosphate-free granular lane.CI Machine Dishwash P-TypeSpotting appears after the change — reset rinse feed for the new chemistry.
S2Cloudy or etched glasswareWashReduce concentration or temperature before changing product.CI Bar Glass CleanerCI Sprinse Rinse AdditiveEtching is permanent — confirm no second detergent is in the tank.
S3White film or spottingRinseRaise rinse additive feed, then check the delime interval.CI Sprinse Rinse AdditiveCI Scalzoff Acid DescalerFilm returns within days — the water is harder than the interval assumes.
S3Wet ware, slow dryingRinseReset rinse feed to full sheeting.CI Sprinse Rinse AdditiveSheeting will not hold — verify final-rinse temperature and flow.
S4Sanitizer ppm reads lowSanitizeCheck drum level, pump calibration, eductor dilution, and strip freshness.CI Sanitrolppm still short after calibration — confirm no hot-water dilution at the eductor.
S4Odour or aftertaste on beer and wine glassSanitizeMove the whole glass program to non-chlorinated wash and iodine.CI Bar Glass CleanerCI SanitrolOdour persists — audit every product touching the glass line.
S5Foam in the wash tankVerifyConfirm machine detergent only; rinse presoaked ware before racking.CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoakFoam persists after drain and refill — trace the manual chemistry source.
S5Rewash rate climbingVerifyRead the four numbers before changing any product.All four read in band — look at rack loading, scraping, and machine mechanics.
S6Weak spray pattern or slow booster recoveryMaintainRun a delime cycle and shorten the interval.CI Scalzoff Acid DescalerRecovery does not improve — escalate to equipment service.
S6Manual sink workMaintainStandardize one manual detergent for the sink line.CI ZIP Pot & Pan DishWashCI Platinum Dish DetergentCI Soft & GentleNever dosed into a machine tank, under any circumstance.
Rule of thumbIf the answer to a warewash problem is “change the detergent,” check temperature, rinse feed, and the delime interval first. Most sites that are unhappy with their chemistry are running correct chemistry out of calibration.
Shift-frequency lane — verified every operating shiftEscalation column — conditions that change the plan
Section 07 · Control & standardization

Set it right once, then hold the numbers

Commissioning turns the stage architecture into set-points any operator can hold.

Commission the machine with verified sanitizer ppm, detergent feed, rinse performance, and PM intervals, then document the set-points so results do not depend on who is on shift. A warewash program that lives in one supervisor’s head resets every time that person moves on.

Commissioning checklist
1Confirm machine type and rinse logic

Identify high-temp or low-temp operation and confirm one-pump versus two-pump rinse logic before any chemistry is connected. This decides the sanitize lane and the feed architecture.

2Set the detergent feed

Start at 2–4 mL/L through the dispenser, then verify low foam and first-pass cleanliness before adjusting the controller. Record the setting.

3Dial in the rinse additive

Set to full sheeting. Ware should exit with no standing droplets and no breaks in the film, drying in 8–15 seconds.

4Verify the sanitizer

Confirm iodine or chlorine ppm with current test strips on low-temp and bar-glass systems. On bar glass, 0.7 mL/L to a 12 ppm target, with no hot-water dilution at the eductor.

5Stage the presoaks properly

Place the presoak at the scrape station with visible dilution, temperature band, and dwell-time instructions. Staging without instructions is not staging.

6Schedule the delime interval

Set a recurring descale cycle based on measured local hardness rather than guesswork, and put it in the work-order system so it survives staff changes.

KPI dashboard · what to measure
PPM
Sanitizer ppm

Iodine or chlorine reading at the final rinse, logged at least once per shift on low-temp and bar-glass machines.

°F
Final rinse temperature

High-temp 180–195 °F, low-temp around 160 °F, bar glass around 140 °F — read at the rack.

RA
Rinse-aid feed rate

Confirm full sheeting. Adjust immediately if spotting or breaks in the film appear, and always after a delime cycle.

DF
Detergent feed

Conductivity control where available, timed feed where it is not. Log the set-point so drift is visible.

RW
Rewash rate

Racks needing a second pass. This is the number that summarises the whole program — investigate any upward movement.

PM
Delime frequency

Log every delime cycle and tie the interval back to measured water hardness rather than to what is visible on the arms.

Quick selector · start from the symptom
What the site reportsFirst moveProductsWhy
APPEARANCE
“There is white film on glasses and plates.”Raise rinse feed, then delime.CI Sprinse Rinse AdditiveCI Scalzoff Acid DescalerFilm is hard-water residue. Rinse-aid acid strength for the local hardness and a missed delime interval cover most cases before chemistry changes.
“We delimed and it still spots.”Re-set the rinse feed after the delime.CI Sprinse Rinse AdditiveDescaling changes the machine surface and often the effective feed rate. Spotting straight after a delime is a feed problem, not a failed descale.
“The glassware is cloudy.”Reduce concentration or temperature; move to the glass lane.CI Bar Glass CleanerCI Sprinse Rinse AdditiveCloudy glass comes from chlorine contact, etching, over-concentration, or excessive temperature. Etching does not reverse — catch it early.
SOIL & SANITIZING
“Food soil is still on the ware after the cycle.”Clear screens and arms, then check feed.CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoakUnder-dosing, poor mechanical action, and clogged jets look identical from the rack. Rule out the mechanical causes first, then add a presoak for protein-heavy loads.
“The sanitizer ppm is reading low.”Check level, pump calibration, and strip freshness.CI SanitrolProduct level, pump drift, eductor dilution, and expired strips are the four causes. Verify all four before changing the sanitizer.
“The beer glasses smell and the heads fall flat.”Take chlorine out of the glass program.CI Bar Glass CleanerCI SanitrolChlorine in wash or rinse is the cause. Non-chlorinated wash chemistry plus iodine at 12 ppm, with no hot-water dilution at the eductor.
FOAM & MANUAL LINE
“The wash tank is foaming.”Confirm machine detergent only; rinse before racking.CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoakEither a manual detergent has entered the tank or presoaked ware went in unrinsed. Drain, refill, and find the source rather than dosing around it.
“Which detergent for the pot sink?”Standardize one manual product for the sink line.CI ZIP Pot & Pan DishWashCI Platinum Dish DetergentCI Soft & GentleCookware, high-volume sink work, and food-plant duty each have a fit. Pick one as the site standard and keep it out of machine dosing.
“What sanitizes the prep tables?”Use the surface disinfectant, not the machine sanitizer.CI OstroSan QuatFood-contact surface sanitizing is a separate system from machine rinse sanitizing. The two products are not interchangeable in either direction.
Signs the program is out of control
Nobody can name the final-rinse temperature

If the number is not on a log, the sanitize step is an assumption. This is the first thing an inspector asks and the last thing most sites can answer.

Two machine detergents on the shelf

Parallel detergents mean nobody decided. Alkalinity stacks, glass etches, and results cannot be compared between shifts.

Deliming happens when scale is visible

By then it is already restricting flow and insulating elements. Visible scale is a missed interval, not a schedule.

Four numbers logged every shift

Temperature, ppm, sheeting, rewash rate. A dishroom holding these four can diagnose instead of guess.

Rewash rate flat or falling

The single figure that proves presoak, wash, rinse, and sanitize are working together. Track it and defend it.

Set-points on a wall chart

Feed rates, dwell times, ppm targets, and the delime interval documented where the work happens. A documented program survives turnover.

CI360™ Warewash is a task-based program guide, not a substitute for site-specific procedures. Confirm dilution ratios, dwell times, temperatures, and sanitizer concentrations against current product labels, SDS, and the applicable local health authority requirement before use. Sanitizer concentrations and final-rinse temperatures are regulated values — verify them against your jurisdiction. Follow site SOPs, training, PPE, and applicable regulations. Never mix acid descaler with chlorinated or alkaline chemistry. Product names follow the Chem International catalogue; linked names open the product page on chemintonline.com.

CI360™ · Warewash

Need a site-specific commissioning package?

CI360 can be translated into controller set-points and a wall-chart commissioning sheet with feed rates, ppm targets, temperature bands, and a delime interval matched to your machines, your controllers, and your water.

Chem InternationalA division of Aliysha Enterprises Ltd.10770 180 St NW, Edmonton, AB T5S 2S4info@chemintonline.comchemintonline.comISO 9001:2015CANUTEC emergency: 1-613-996-6666

CI360™ · WW · 3 machine classes · 5 injection points · 27 products

A warewash program does not fail because the chemistry is weak. It fails because the final rinse never reached temperature, the sanitizer drifted, or the delime was skipped — and nobody measured any of it.

WarewashBuilt around the job, not the catalogue.

Section 01 · Where the chemistry actually goes

Five points. Five jobs. No overlap.

A warewash problem is almost always a point problem — the wrong chemistry at the right point, or the right chemistry at a point that is not being measured.

SheetWW-01 · Conveyor machine in section
ProgramHigh-temperature machine
Control pointFinal rinse 180°F / 82°C
Points5
CONVEYOR MACHINE · SECTIONPREWASHWASH TANKRINSEPRESOAK SINKDRY / STACK12345CHEMISTRY ENTERS HERE — FIVE POINTS, FIVE JOBSFINAL RINSE 180°F / 82°C — VERIFY FIRST
1
Presoak sink

Protein, tannin, silver and plastic staining — broken before the rack ever loads. Presoak is not one bucket for everything.

Presoak by soil typeJ565 · J420 · J413 · J415 · J477
CHANGE PER SHIFT
2
Prewash / scrap

Bulk soil removed mechanically. Rinse presoaked ware here so presoak residue never reaches the wash tank.

—NO CHEMISTRY
SCREENS AND JETS CLEAR
3
Wash tank detergent

Match the detergent to the machine before adjusting the dose. Under-dose shows as soil left on ware; the wrong detergent shows as foam.

Machine detergentJ430 · J408 · J428 · J440
2–4 mL/L · LOW FOAM
4
Final rinse injector

Rinse additive sheets the water so heat can do the drying. On a low-temp or bar-glass machine this point also carries the sanitizer. Temperature is verified first, always.

Rinse additive · sanitizer where requiredJ441 · J433 · J439 · CI SPRINCE · J438 · J478 · CI SANITROL · J436 · J437
180°F AT THE RACK · PPM BY STRIP
5
Dry / stack

No chemistry. If ware is wet or spotted here, the fault is upstream at point 4 or in the delime interval — not a drying problem.

—NO CHEMISTRY
NO TOWEL DRYING

The section is the navigation. Callout circles are anchors — clicking 3 jumps to the wash-tank module. On a phone the drawing scrolls and the numbered key below carries the same five points in the same order, so the printed sheet and the screen always agree.

Section 02 · What has to hold

Four numbers decide whether the program is working.

A clean-looking rack does not prove the machine is operating correctly. Nothing below this panel matters if these four are out of band.

Warewash · control targetsBands as published · verify on site
Final rinse temperature≥ 180°F / 82°C
140TARGET ≥ 180°F HIGH-TEMP200°F

Verified at the rack, not at the gauge on the door. Ticks mark the other two machine classes: bar glass around 140°F, low-temp around 160°F / 71°C — both of which require a verified chemical sanitizer instead.

Machine detergent feed2–4 mL/L
0TARGET 2–4 mL/L6 mL/L

Auto-feed setting for J430 and J440, adjusted to soil load and water hardness. Confirm low foam and first-pass cleanliness before moving the controller.

Bar glass iodine · final rinse12 ppm
0TARGET 12 PPM · 0.7 mL/L25 ppm

CI Sanitrol calibrated to 12 ppm at the final rinse. Do not dilute iodine with hot water at the eductor — it strips the residual you just paid for.

Enzyme presoak bath37–50°C
20TARGET 37–50°C · 1:20 · 10 MIN70°C

J565 at 1:20 with at least ten minutes of dwell. Too cold slows enzyme activity; above roughly 50°C the protease denatures and the bath is doing nothing.

Every band on this panel is published, not estimated. Where a value depends on the site — water hardness, soil load, controller type — the page gives the method and the frequency instead of a number. Nothing here gets a figure it cannot defend.

Section 03 · One module per point

Start with the rinse temperature. Chemistry second.

The program starts with one question: what final-rinse temperature is the machine actually delivering? That answer decides detergent choice, rinse logic, sanitizer requirement, and the PM schedule that keeps the machine out of film, spotting, rewashes, and failed sanitization.

ORDER 01Verify temperatureRead the final rinse at the rack before touching any chemistry. Everything downstream is built on this number.
ORDER 02Match the detergentTo the machine and its temperature profile — high-temp, low-temp, or bar glass. Match first, then adjust the dose.
ORDER 03Set the rinseDial rinse additive to full sheeting. Ware should leave with no standing droplets and no breaks in flow.
ORDER 04Prove the sanitizerThermal on a high-temp machine, verified ppm everywhere else. A clean rack is not proof.
1

Presoak sink · before the rack

Presoak is not one bucket for everything. Protein, tannin, silver, plastic staining and mixed soil each need their own lane, so the machine is not forced to solve every problem alone. Rinse presoaked ware before racking or the residue foams the wash tank.

Default · general mixed loadWhere no specialized chemistry is required
J413 Liq. Warewash Presoak CLGeneral liquid presoak
Escalation · named soilDeployed when the machine is leaving a specific soil behind
J565 WareWash Enzyme PreSoakProtein · 1:20 · 37–50°C · 10 min
J420 Melamine Chlorinated PresoakTannin · china and melamine
Controlled · substrate-restrictedMatched to the ware, not to the soil load
J415 Silver Pre Soak NCNon-chlorinated · silver only
J477 D-StainAlkaline peroxide · stubborn plastic stains
Skip it and

Main-wash aggression gets raised to compensate for soil that should have been released in the sink. Flatware still comes back with protein, plastics still stain, and the detergent cost climbs while first-pass results get worse.

2

Prewash / scrap · no chemistry

Bulk soil comes off mechanically here. This point exists on the sheet precisely because nothing should be dosed into it — and because it is where presoaked ware gets rinsed before racking. Screens, jets and wash arms clear at this point are worth more than any dose change downstream.

Fails as

Excessive foaming in the wash tank, traced back to unrinsed presoak residue or a manual detergent that was never meant to enter the machine. Drain and refill if the foam persists.

3

Wash tank detergent · match the machine first

Three machine classes, three detergent lanes. The lane is decided by the machine's temperature profile and its sanitizing method — not by soil load, and not by preference. Dose 2–4 mL/L by auto-feed and adjust to soil and water hardness only after the lane is right.

Default · high-temperature machine≥ 180°F / 82°C · sanitizes thermally
J430 CI Machine Dishwash L-TypeLiquid · 2–4 mL/L · hard-water performance
J408 CF Machine Dishwash PowderPhosphate-free granular · active oxygen
Escalation · low-temperature machine~160°F / 71°C · chemical sanitizer mandatory
J428 Low Temp Liq. Machine DishMunicipal chlorine or chloramine sites
J430 CI Machine Dishwash L-TypeWhere approved for the machine
Controlled · bar glass washer~140°F / 60°C · non-chlorinated wash only
J440 E-8 Bar Glass CleanerNon-chlorinated low-foam · 2–4 mL/L
Non-negotiable split

High-temp machines sanitize thermally. Low-temp machines require a verified chemical sanitizer. Bar glass needs non-chlorinated wash chemistry and tightly controlled iodine ppm. Chlorine in a glass program drives odour, film and spotting — it is not a dose problem, it is the wrong lane.

4

Final rinse injector · sheeting, then sanitizing

Two jobs share one point. Rinse additive sheets the water so heat can dry the ware; on any machine that does not reach 180°F, this point also carries the sanitizer. Where the machine has two rinse pumps, keep rinse aid and sanitizer separate. Where it has one, use combined feed only if the controller and the product were designed for it.

Default · rinse additiveTarget full sheeting — no droplets, no breaks in flow
J441 All Temp RinseMild acid · sheeting and scale control
CI Sprince Rinse AdditiveHouse rinse · mixed equipment fleets
J439 All Temp Econo-RinseEconomy tier · low-temp systems
J433 Glass BriteBar glass clarity and sheeting
Escalation · low-temp sanitizerMandatory below the thermal threshold · verify ppm every shift
J438 K-13 LF Ostro DineIodine · glass-friendly, low odour
J478 K-10 LF Ostro DineAlternate iodine concentration
J436 Liquid Chlorine Sanitizer 12%Chlorine lane
J437 Liquid Chlorine Sanitizer 6%Reduced-strength chlorine lane
Controlled · bar glass final rinseIodine only · calibrated, never estimated
CI Sanitrol12 ppm at 0.7 mL/L · no hot-water dilution
Out of band

Sanitizer ppm below the threshold is a stop-work condition, not a note for the next shift. Check product level, pump calibration and eductor dilution, and re-test with a fresh strip from the current lot before changing anything else.

5

Dry / stack · no chemistry

Nothing is dosed here, and nothing should be corrected here. Wet ware is a point-4 fault — rinse-additive feed or final-rinse temperature. Spotted ware is a hardness and delime fault. Towel drying hides both and re-contaminates sanitized ware.

Fails as

An operator who reaches for a towel instead of the rinse-aid setting. The symptom stops appearing and the underlying drift keeps running until the descale interval is missed too.

—

Off-point · machine PM and everything outside the machine

Two lanes that belong to the warewash program but do not sit on the drawing. Deliming is scheduled maintenance, not a detergent. Manual sink chemistry is a separate system and never enters the machine.

Machine PM · delimingInterval set by actual water hardness, not guesswork
J434 DescalerDish machines · glass washers · coffee equipment
J435 M-37 DescalerAlternate acid descaler
CI ScalzoffNon-foaming · rapid mineral removal
Outside the machine · manual sink and surfacesNever dosed into a machine — these foam
CI ZIP Lemon Liquid DishWashManual · 15 mL per 10 L starting point
J481 Platinum Dish DetergentSuper-concentrate · high-volume sinks
J431 / J432 / J444 Pink · Lemon · Wild CherryManual detergent fragrance alternates
J465 Ostro San QuatFood-contact surfaces · not a machine rinse sanitizer
Tight shelf principle

Warewash systems fail when a site piles on overlapping detergents, mixed rinse chemistry and a random sanitizer choice. Every product above answers to one point and one job. If two products are doing the same job on the same pass, one of them is the problem.

Section 04 · Out of band

Most warewash failures are drift, not chemistry.

Film, spotting, rewashes and failed sanitization are usually a feed problem, a temperature problem, or a PM problem. Work the ladder in order — changing the product first is the most expensive way to find that out.

The correction ladder · run it on every control target, in this order

Step 01 · Verify
Prove the reading

Re-test with a fresh strip from the current lot, or a calibrated thermometer at the rack. Half of all "chemical failures" are measurement failures.

Step 02 · Mechanical
Check the machine first

Pump calibration, eductor dilution, product level, screens, wash arms, booster temperature. Chemistry cannot fix a pump that is not pulling.

Step 03 · Adjust
Correct the dose

One change at a time, back to the labelled setting. Record the reading before and after — not just the controller setting.

Step 04 · Escalate
Change the chemistry

Only now. If the machine class, water condition or soil load has genuinely changed, move lanes — do not stack a second product on top of the first.

Field translation · observed condition to corrective action

Symptom
Probable cause
Corrective action
White film on glasses or plates
Mineral scale, underfed rinse aid, irregular deliming.
Increase CI Sprince or J441 feed. Run CI Scalzoff or J434 / J435. Check booster temperature and final-rinse flow.
Spots persisting after deliming
Rinse and sanitizer mismatch, or rinse-aid underfeed left uncorrected after the descale.
Re-set the rinse-aid feed rate after every delime. On bar glass, move to iodine at 12 ppm and verify sheeting.
Cloudy or etched glass
Chlorine contact, excessive detergent concentration, or excessive temperature.
Switch to J440 for glass, reduce concentration or temperature, and confirm clean sheeting with J433.
Food soil remaining after the cycle
Under-dosing, poor mechanical action, clogged jets or screens.
Raise J430 or J428 within spec, clean screens and wash arms, and stage J565 for protein-heavy loads.
Odour or aftertaste in beer and wine glasses
Chlorine in the glass program, sanitizer overfeed, or hot-water dilution at the eductor.
Run a non-chlorinated glass program with iodine at 12 ppm. Verify ppm and eliminate hot-water dilution at the eductor.
Excessive foaming in the wash tank
Wrong detergent in the machine, or presoak residue that was never rinsed off.
Confirm low-foaming machine detergent only. Rinse presoaked ware before racking. Drain and refill if foam persists.
Sanitizer ppm too low
Pump calibration drift, eductor dilution error, or an empty product drum.
Check product level, recalibrate the pump, and verify with fresh test strips from the current lot.
Rule of thumb

Most spotting and film traces back to two things before anything else: insufficient rinse-aid acid strength for local hardness, or a missed descale cycle. Fix those before changing detergent chemistry.

Section 05 · Ready-to-deploy site logic

Three machine classes. Pick the one you actually run.

The difference between these columns is not quality. It is what the machine is physically able to do — and therefore what has to be measured to prove it is working.

Program
A · High-temp machineRack conveyor or door type
DEFAULT ROUTE
B · Low-temp machineChemical sanitizing
C · Bar glass washerClarity-controlled
Site signature
Final rinse verified at 180°F / 82°C or above. Sanitizing is thermal and needs no chemical assistance.
Final rinse around 160°F / 71°C. Sanitizing is chemical and is only as good as the last strip reading.
Final rinse around 140°F / 60°C. Glass clarity is the controlling objective, not soil removal.
Point 1 · Presoak
By soil typeJ565 · J420 · J413 · J415 · J477
By soil typeJ565 · J420 · J413 · J415 · J477
Not applicable
Point 3 · Detergent
J430 CI Machine Dishwash L-Type2–4 mL/L · J408 POWDER ALT
J428 Low Temp Liq. Machine DishJ430 WHERE APPROVED
J440 E-8 Bar Glass Cleaner2–4 mL/L · NON-CHLORINATED
Point 4 · Rinse additive
J441 All Temp RinseCI SPRINCE ALT
J441 All Temp RinseJ439 ECONO ALT
J433 Glass BriteCLARITY-OPTIMIZED
Point 4 · Sanitize
ThermalNO CHEMICAL SANITIZER IN CYCLE
J438 iodine or J436 chlorineJ478 / J437 ALT · PPM BY STRIP
CI Sanitrol iodine12 PPM AT 0.7 mL/L · NO CHLORINE
PM · Deliming
J434 / J435 / CI ScalzoffHARDNESS-BASED INTERVAL
J434 / J435 / CI ScalzoffHARDNESS-BASED INTERVAL
J434 / J435 / CI ScalzoffHARDNESS-BASED INTERVAL
Swap if
The final rinse cannot be verified at 180°F — the site is running Program B whether it knows it or not.
The machine has two rinse pumps — separate rinse aid from sanitizer instead of combining feed.
Odour or film appears in the glass — chlorine has entered the program somewhere. Remove it, do not dose around it.

The rows never change. Site signature, then the points in drawing order, then PM, then swap-if. Every CI360 application publishes the same seven rows with different columns, so a reader who has read one page can read all five.

Section 06 · Build the stack

Answer three questions. Leave with a stack you can order.

Everything above this point is reasoning. This is where it resolves into a named product at every point, with the dose and the control target attached — the same sheet a rep would write on your counter.

CI360™ · WW · Stack builder
Step 1 of 2

The stack builder does not price anything. It returns products, points, doses and control targets — the specification. Pack sizes and price are set against your water report and volumes when the request comes through.

Section 07 · The kit

Program A · high-temperature site kit

Nothing in this kit does the same job twice — which is the entire reason it is published as a kit instead of a category.

Product
Point / role
Dose
Control
J565 WareWash Enzyme PreSoak
1 · Presoak, protein
1:20
37–50°C · 10 MIN
J413 Liq. Warewash Presoak CL
1 · Presoak, mixed load
PER LABEL
CHANGE PER SHIFT
J430 CI Machine Dishwash L-Type
3 · Wash tank detergent
2–4 mL/L
LOW FOAM · FIRST-PASS CLEAN
J441 All Temp Rinse
4 · Rinse additive
TO SHEETING
NO DROPLETS OR BREAKS
J434 Descaler
PM · Deliming
PER LABEL
HARDNESS-BASED INTERVAL
J481 Platinum Dish Detergent
Off-point · manual sink
PER LABEL
OUTSIDE THE MACHINE ONLY

Have this kit reviewed against your water report, your machine's verified final-rinse temperature, and your controller before you order. Program B and C kits substitute at points 3 and 4 only.

Request this kit →

No pricing on this page. The kit carries products, points, doses and control targets. Pack sizes and price stay behind the quote request, as they do everywhere else on the site.

Section 08 · Commissioning and control

Set it right once, then lock the set-points down.

Commission the machine with verified ppm, mL/L and temperature targets, then document the set-points so any operator on any shift can hold them without guesswork.

STEP 01Confirm machine and rinse logicIdentify high-temp or low-temp operation, and confirm one-pump versus two-pump rinse logic, before adding any chemistry.
STEP 02Set detergent feedStart J430 or J440 at 2–4 mL/L, then verify low foam and first-pass cleanliness before adjusting the controller.
STEP 03Dial in rinse aidSet the rinse to full sheeting. Ware should exit with no standing droplets and no breaks in flow.
STEP 04Verify sanitizer ppmConfirm iodine or chlorine ppm with current test strips each shift, especially on low-temp and bar-glass systems.
STEP 05Stage presoaks properlyPlace J565 and any other required presoak at the scrape station with dwell-time and temperature instructions visible.
STEP 06Schedule PM delimingSet a recurring CI Scalzoff or J434 / J435 interval based on actual local hardness, not on guesswork.

Verification schedule · what is measured, how, and how often

Value
Why it matters
Method
Frequency
Final rinse temperature
Sanitizing is thermal on a high-temp machine. Below band, nothing else compensates.
THERMOMETER AT THE RACK
EVERY SHIFT
Sanitizer ppm
The only sanitizing control on a low-temp or bar-glass machine. A failed strip is a stop-work condition.
TEST STRIP · CURRENT LOT
EVERY SHIFT
Rinse-aid feed rate
Sheeting is what lets heat dry the ware. Spotting and breaks in flow mean the feed has drifted.
VISUAL · SHEETING CHECK
EVERY SHIFT
Detergent feed
Under-dosing leaves soil; the wrong detergent foams. Both look like a product problem and are not.
CONDUCTIVITY OR TIMED FEED
DAILY
Presoak bath
A spent or out-of-temperature presoak redeposits the soil it removed onto the next load.
TEMPERATURE · VISUAL · LOG
PER SHIFT
Rewash rate
The one KPI that catches every other drift. Any upward movement is a signal before it is a complaint.
RACK COUNT · LOG
WEEKLY TREND
Descale frequency
Visible scale means the interval was already too long. Tie it to measured hardness, not to the calendar.
DELIME LOG · WATER REPORT
BY HARDNESS

This is the whole program. Chemistry that is not measured is not a program — it is inventory. The verification schedule above is what turns the products on this page into a result the site can defend to an inspector.

CI360™ · WW · Warewash

Start with actual rinse temperature. Everything else follows from it.

Match the detergent to the machine, the rinse aid to the water, and the sanitizer to the application. Verify ppm, verify sheeting, and delime on schedule. Most warewash failures come from drift, not from a lack of chemistry.

Chem International can translate this sheet into controller set-points and a commissioning checklist matched to your exact machines, controllers and water report.

Chem International · Aliysha Enterprises Ltd. 1-800-665-7287 info@chemintonline.com chemintonline.com 10770 180 St NW, Edmonton, AB T5S 2S4 Founded 1988 · ISO 9001:2015 CANUTEC 613-996-6666