Warewash programs do not fail on chemistry. They fail on drift — a final-rinse temperature nobody has measured this month, a sanitizer pump that quietly lost calibration, a delime interval set by habit instead of water hardness.
WarewashStart with the temperature the machine is actually delivering.
One rack cycle, six stages — and every product owns exactly one of them
Six stages. One rack cycle. Three machine programs.
CI360™ is a task-based program, not a product shelf. Warewash runs as a closed cycle: presoak, wash, rinse, sanitize, verify, maintain — and back to the next rack. Each stage has one job and one product lane. The program fails when the lanes blur: two detergents in one machine, a hand-sink detergent poured into a machine tank, chemical sanitizer stacked on top of a machine that already sanitizes with heat, or a delime cycle that only happens when scale is visible on the arms.
The controlling variable is temperature. What the final rinse actually delivers decides the detergent, the rinse logic, whether a chemical sanitizer is required at all, and how tight the deliming interval has to be. Every other decision on this page follows from that one measurement — and it has to be a measurement, not an assumption.
- Presoak releases protein before the rack, so the machine is not over-dosed to compensate.
- One machine detergent carries the wash — liquid, granular, or non-chlorinated glass.
- Rinse additive controls hard-water residue and produces sheeting, not droplets.
- The sanitize step is either heat or verified chemistry — never both on the same rack.
- Verification is a stage with its own outputs: temperature, ppm, sheeting, rewash rate.
- Deliming runs off the daily line, on an interval set by water hardness.
- Raising detergent feed to chase a problem that belongs in the presoak sink.
- Adding chemical sanitizer to a high-temp machine that is already sanitizing thermally.
- Running chlorine chemistry through a bar glass program and calling the result a rinse problem.
- Changing products before verifying temperature, feed rate, and delime interval.
- Treating the three-compartment sink and the machine as one chemistry system.
Presoak
Protein released before the rack, so the wash stage is not asked to solve it alone.
“The machine should not be asked to solve a problem that belongs in the presoak sink. Raising detergent feed to chase protein soil etches glass and films ware.”
Presoak is a staged step, not a standing bucket. It earns its place where protein soil recurs — egg, dairy, meat, and baked-on organic residue on flatware. Enzymes need both temperature and time: hold the bath between 37–50 °C, because colder water slows the protease and hotter water denatures it. Then rinse the ware before racking, or presoak residue carries into the wash tank and foams the pump.
Silver flatware — non-chlorinated presoak where tarnish risk rules out chlorine chemistry.
Plastic and melamine staining — oxidative lift for tomato, curry, and turmeric.
General mixed loads — where no enzyme, silver-safe, or stain-lift chemistry is required.
| Task / condition · best-fit products | Why it belongs · operator note | |
|---|---|---|
| 1 | Scrape and scrap before the bath | Gross soil belongs in the scrap opening, not in presoak chemistry.A presoak bath loaded with food debris stops working within an hour. Scraping is the cheapest step in the dishroom and the one most often skipped when the line backs up. |
| 2 | Protein soil on flatwareCI WareWash Enzyme PreSoak | 20X concentrated protease presoak for egg, dairy, meat, and baked-on protein; safe on silver and stainless steel.Stage it where protein soil recurs, not everywhere by default. Where the soil does not justify it, the stage is skipped and the machine carries the load. |
| 3 | Bath temperature | 37–50 °C is the working band for the protease.Below the band the enzyme is slow; above it the enzyme is destroyed and you are soaking in warm water. Put a thermometer in the bath and treat the band as a set-point, not a preference. |
| 4 | Dwell time | Ten minutes minimum. Time is what the enzyme uses.Shortening dwell to keep the line moving is what pushes protein soil into the wash tank. If the bath cannot hold ten minutes, the bath is undersized for the volume. |
| 5 | Rinse before racking | Presoaked ware carries presoak chemistry into the machine.This is the single most common cause of foam in a wash tank that is otherwise correctly dosed. Rinse the flatware, then rack it. |
Presoak earns its place — or it does not run.
- Soil is mixed food debris rather than baked-on protein.
- Flatware reaches the machine within a shift, not the next morning.
- First-pass results are clean and the rewash rate is flat.
- The wash stage is correctly dosed and verified.
- Egg, dairy, and meat residue is a daily recurring soil.
- Flatware sits before it reaches the machine.
- Flatware comes off the rack filmed while plates come off clean.
- Detergent feed is being raised to compensate for one soil type.
Scrape → soak → rinse → rack.
The presoak stage exists to change what enters the wash tank. Every gram of protein released in the sink is soil the machine does not have to carry, alkalinity it does not have to spend, and water it does not have to change early. Where the stage is running correctly, the wash tank stays cleaner for longer and the rewash rate drops without a single change to the detergent.
Over-dosing machine detergent to solve a presoak problem etches glassware, films ware, and raises chemical cost on every rack in the building to fix a soil that appears on one. Fix the stage that owns the problem.
Flatware returns for a rewash while plates and glassware come off clean. Protein film appears on tines and spoon bowls. Detergent consumption is climbing with no change in cover count. Operators describe the detergent as “not working like it used to.”
Foam in the wash tank shortly after a presoak batch is racked — ware was not rinsed. A bath that is hot to the touch — the protease is denatured and the soak is doing nothing. A bath left standing all shift, loaded with debris, doing less than plain water.
Wash
One detergent per machine, matched to the final-rinse temperature and the water it runs on.
“One detergent per machine. Two is not insurance — it is double alkalinity, etched glassware, and a rinse problem you will spend a week chasing.”
The wash stage is where soil is removed, and it is the only stage where the choice of product is genuinely a choice. Liquid alkaline covers most high-temp and many low-temp machines and holds performance in hard water. Phosphate-free granular is the lane where discharge is restricted or a dry feed suits the site. Non-chlorinated glass chemistry is a separate lane entirely, because chlorine is what puts odour and film on beverage glass.
Set the feed at 2–4 mL/L through the dispenser, then verify low foam and first-pass cleanliness before touching the controller again. If ware is coming out clean but not clear, the answer is almost always rinse aid or scale — not more detergent.
| Task / condition · best-fit products | Why it belongs · operator note | |
|---|---|---|
| 1 | Scrap screens and wash arms | Chemistry cannot reach ware that the spray pattern is not hitting.Clogged jets and loaded screens read exactly like an under-dosed detergent. Clear them before you touch the feed rate — it is a two-minute check that resolves a large share of “soil remaining” calls. |
| 2 | High-volume machine wash · hard waterCI Machine Dishwash L-Type | Concentrated high-alkaline liquid with sequestering agents for grease, baked-on protein, and hard-water minerals; runs across high- and low-temp systems.This is the default lane. Hard water and heavy food soil are the conditions it was built for, and one liquid covering both machine types keeps the dishroom on a single SKU. |
| 3 | Phosphate-restricted or dry-feed sitesCI Machine Dishwash P-Type | Phosphate-free granular with an active-oxygen system, built-in water softeners, protein removers, and free-rinsing wetting agents.Choose it for the discharge requirement or the dispenser format, not for performance ranking. It is a parallel lane to the liquid, not a step above or below it. |
| 4 | Bar, glass, and bottle washersCI Bar Glass Cleaner | Non-chlorinated, low-foaming liquid for automatic glass and bottle washers — cuts beverage residue, lipstick, and protein film without chlorine.Do not substitute a dish detergent here. Chlorine residue transfers taste and smell to the next pour and kills head retention on beer glass. |
| 5 | Detergent feed rateCI Machine Dishwash L-TypeCI Bar Glass Cleaner | 2–4 mL/L through the dispenser, adjusted to soil load and water hardness.Set it, verify it, and log it. A feed rate adjusted by eye every time someone is unhappy with a rack is the fastest route to both etched glass and unexplained chemical spend. |
| 6 | Foam in the wash tank | Machine detergents are low-foam by specification.Foam means either manual chemistry has entered the tank or presoaked ware was racked unrinsed. Drain, refill, and find the source — do not dose a defoamer into a warewash tank as a routine fix. |
Liquid or granular is a site decision, not a performance one.
- Water is hard and sequestration is doing real work.
- The site already runs liquid dispensing equipment.
- One detergent has to cover both a high-temp and a low-temp machine.
- Soil load is heavy and variable across the day.
- Phosphate discharge is restricted by the receiving system.
- A dry feed suits the dispenser and the storage.
- Active-oxygen stain removal is wanted on china and melamine.
- Built-in softeners are preferred over separate treatment.
Clean, but not clear, is a rinse problem.
The most common misread in a dishroom is treating a clarity problem as a detergent problem. Ware that comes off the rack clean but spotted, filmed, or hazy is telling you about hard-water residue, rinse-aid feed, or scale — all downstream of the wash stage. Raising detergent in response makes the glass worse and the invoice larger.
Running a liquid and a granular together doubles alkalinity in the tank, etches glassware permanently, and produces a film that no rinse additive can correct. If a second detergent is on the shelf for a second machine, label the dispensers and keep them apart.
Rinse & Sanitize
Sheeting rather than droplets — and a kill step you can put a number on.
“Sheeting is not cosmetic. Water that beads is water still carrying hardness onto the ware — and it will dry there.”
The final rinse does two jobs on the same pass. The rinse additive neutralizes hard-water residue and drops surface tension so water leaves the ware as one unbroken film. The sanitize step is either heat or chemistry, decided entirely by what the machine actually delivers: thermal on a machine holding 180–195 °F at the rack, verified iodine or chlorine on a low-temp machine, and iodine at 12 ppm on bar glass.
Where a machine has two rinse pumps, keep rinse aid and sanitizer in separate lanes. Where it has one, use a combined feed only if both the controller and the product are designed for it. And never dilute iodine with hot water at the eductor — it strips the residual you are trying to verify.
| Task / condition · best-fit products | Why it belongs · operator note | |
|---|---|---|
| 1 | Final-rinse temperature | 180–195 °F (82–91 °C) on a high-temp machine, measured at the rack.Heat sanitizing only happens at temperature. A clean-looking rack is not proof, and the panel gauge reads the manifold rather than the ware. Use a dishwasher-safe thermometer or thermal strip. |
| 2 | Rinse additive feedCI Sprinse Rinse Additive | Non-foaming rinse additive with wetting agents and mild acid for rapid sheeting and hard-water residue control on ware and machine internals.Water should leave the ware as one unbroken film and dry in 8–15 seconds. Standing droplets mean the rinse feed needs adjusting — before anyone touches the detergent. |
| 3 | Thermal sanitizing · high-temp machines | The heat is the kill step. No chemical sanitizer belongs in the cycle.Adding sanitizer on top of a machine that is already sanitizing thermally buys nothing, costs money, and can taint glassware. If the machine cannot hold temperature, move it to the chemical lane and re-verify — do not run both. |
| 4 | Chemical sanitizing · low-temp machinesCI Sanitrol | Verified iodine at the final rinse where the machine runs around 160 °F (71 °C).This is the kill step and a health-code number, not a preference. Confirm with fresh strips from the current lot at least once per shift, and log the reading. |
| 5 | Bar glass · iodine at 12 ppmCI SanitrolCI Bar Glass Cleaner | 0.7 mL/L to a 12 ppm iodine target in the final rinse, paired with non-chlorinated wash chemistry.Do not dilute iodine with hot water at the eductor. Hot-water dilution is the most common reason a correctly set pump still reads short on the strip. |
| 6 | Odour or aftertaste on beverage glassCI Bar Glass CleanerCI Sanitrol | Chlorine contact anywhere in the glass program transfers taste and smell to the next pour.Move the whole program to non-chlorinated wash chemistry and iodine, then verify ppm and eliminate hot-water dilution. Flat beer heads and “wine tastes off” are the same fault reported two ways. |
The machine decides the kill step. Not the preference of the site.
- The final rinse holds 180–195 °F measured at the rack.
- The booster recovers between racks at full production rate.
- Descaling is on interval and elements are clear.
- Temperature is logged, not assumed.
- The machine runs low-temp at around 160 °F.
- It is a bar or bottle glass washer at around 140 °F.
- The booster cannot hold temperature at production rate.
- Local requirement specifies a chemical residual.
Check first · film or spotting.
Where the machine has separate rinse and sanitizer pumps, keep the products separate. Where there is a single pump, a combined feed is only acceptable if both the controller and the product are designed for it. Improvising here produces a rinse that under-delivers on both jobs.
Verify & Maintain
The exit read, the shift log, the delime interval — and the manual line that runs beside the machine.
“Most warewash failures are drift, not chemistry. Verify temperature, feed, and delime interval before you change a single product.”
Verification is a stage, not an afterthought. Four readings — final-rinse temperature, sanitizer ppm, sheeting behaviour, and rewash rate — catch nearly all warewash drift before it reaches a customer or an inspector. None of them takes more than a minute, and all four belong on a shift log rather than in someone’s memory.
Deliming is the maintenance stage that keeps the rest honest. Missed delime cycles are the most common cause of film, cloudy glass, weak spray pattern, and a booster that no longer reaches temperature. Set the interval by measured water hardness and run it off the daily line — never during service, and never in the same cycle as detergent or sanitizer. The manual three-compartment line runs beside all of this on its own chemistry, and that chemistry never enters machine dosing.
| Task / condition · best-fit products | Why it belongs · operator note | |
|---|---|---|
| 1 | The exit read | Dry ware with no standing droplets in 8–15 seconds is the program working.Spots, film, or wet stacks each point back to a specific stage. Read the rack every shift and treat what you see as a diagnostic, not a complaint. |
| 2 | The shift log | Final-rinse temperature, sanitizer ppm, sheeting, and rewash rate.A program that lives in one supervisor’s head resets every time that person moves on. Four numbers on a wall sheet survive staff turnover; a verbal standard does not. |
| 3 | Scale control and delimingCI Scalzoff Acid Descaler | Non-foaming acid descaler that dissolves calcium, lime, and magnesium scale in dish machines, glass washers, and other water-fed equipment.Set the interval by measured hardness. Run it off the daily line, never during service, and never in the same cycle as detergent or sanitizer. |
| 4 | Pot, pan, and three-sink workCI ZIP Pot & Pan DishWashCI Platinum Dish DetergentCI Soft & Gentle | High-suds lemon liquid for baked-on cookware; a 2X neutral-pH concentrate for high-volume sinks; a food-plant manual detergent effective across all water conditions.Pick one as the site standard for the sink and keep it there. These are high-suds by design — one pour into a machine tank foams the wash pump dry. |
| 5 | Food-contact surfaces outside the machineCI OstroSan Quat | Quaternary ammonium disinfectant and deodorizer for food-contact surfaces and general kitchen sanitizing, DIN 02465116.Surface sanitizing and machine rinse sanitizing are separate systems with separate products. Do not substitute one for the other in either direction. |
| 6 | Rewash rate | Racks that need a second pass, tracked as a number.Rewash rate is the single figure that summarises presoak, wash, rinse, and sanitize together. Any upward movement is a signal to check the four readings before anyone reaches for a different product. |
The delime interval is set by the water, not the calendar.
- Incoming water is soft or softened at the building.
- Rinse additive feed is verified and sheeting is holding.
- Spray arms and jets are clear on inspection.
- Booster recovery is holding at full production rate.
- Incoming water is hard and untreated.
- Film returns within days of a delime cycle.
- Spray pattern weakens between scheduled cycles.
- The booster is slower to recover than it was.
Read → log → correct → delime.
Verification exists so that corrective action is aimed at the right stage. A dishroom that logs four numbers can tell the difference between an under-dosed tank, a drifting sanitizer pump, a rinse feed that needs resetting after a delime, and a machine that simply needs descaling. A dishroom that logs nothing can only change products and hope.
Descaling changes the surface condition of the machine and, on many systems, the effective rinse feed rate. Spotting that appears immediately after a delime cycle is almost always a rinse-aid feed that needs re-setting — not evidence that the descale was wrong.
Machine detergent, manual sink detergent, machine rinse sanitizer, and surface disinfectant are four systems, not four options. Every warewash program that collapses does so by letting one of them wander into another’s job.
Deliming never runs during service and never shares a cycle with detergent or sanitizer. Schedule it, log it, and tie the interval back to the actual water — not to the last time somebody noticed scale on the arms.
One system, three machine programs — what changes is the kill step, not the logic
The stage sequence stays fixed. Temperature decides the sanitize lane and the chemistry that supports it.
CI360 warewash scales from a single undercounter glass washer to a rack conveyor in an institutional kitchen on the same six stages. What moves between deployments is the final-rinse temperature and therefore the sanitize step — thermal above 180 °F, verified chemistry below it, and iodine at a tightly controlled 12 ppm on bar glass.
High-Temperature Machine
Rack conveyor or door type · ≥ 180 °F / 82 °C final rinse
Machine Dishwash L-Type at 2–4 mL/L, or P-Type where a phosphate-free granular suits the site.
Sprinse Rinse Additive, set to full sheeting with no droplets or breaks on the ware.
Thermal. No chemical sanitizer in the cycle where the final rinse genuinely holds temperature.
Scalzoff on a delime interval set to local water hardness.
Low-Temperature Machine
Chemical sanitizing · around 160 °F / 71 °C final rinse
Machine Dishwash L-Type where approved for the machine and the water.
Sprinse Rinse Additive for sheeting and hard-water residue control.
Sanitrol iodine at the final rinse, verified with fresh test strips every shift. This is the kill step.
Two rinse pumps: keep rinse aid and sanitizer separate. One pump: combined feed only where the controller and product allow it.
Bar Glass Washer
Non-chlorinated wash · around 140 °F / 60 °C · iodine final rinse
Bar Glass Cleaner at 2–4 mL/L — non-chlorinated, for film-free glass with no odour transfer.
Sprinse Rinse Additive for clarity and sheeting; head retention on beer glass depends on it.
Sanitrol at 0.7 mL/L to a 12 ppm iodine target. Do not dilute with hot water at the eductor.
Chlorine anywhere in the glass program. It is what drives odour, film, and spotting on glassware.
| Condition in the dishroomWhat you are actually looking at | StageWhere it belongs in the cycle | First moveDo this before anything else | Products | Escalate only if… |
|---|---|---|---|---|
| S1Protein film on flatware | Presoak | Stage an enzyme presoak before the rack. | CI WareWash Enzyme PreSoak | Film persists after a correct soak — check dwell and bath temperature. |
| S2Food soil remaining after the cycle | Wash | Clear screens and arms, then confirm feed within spec. | CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoak | Soil remains at correct feed — check mechanical action and rack loading. |
| S2Phosphate discharge restricted | Wash | Move to the phosphate-free granular lane. | CI Machine Dishwash P-Type | Spotting appears after the change — reset rinse feed for the new chemistry. |
| S2Cloudy or etched glassware | Wash | Reduce concentration or temperature before changing product. | CI Bar Glass CleanerCI Sprinse Rinse Additive | Etching is permanent — confirm no second detergent is in the tank. |
| S3White film or spotting | Rinse | Raise rinse additive feed, then check the delime interval. | CI Sprinse Rinse AdditiveCI Scalzoff Acid Descaler | Film returns within days — the water is harder than the interval assumes. |
| S3Wet ware, slow drying | Rinse | Reset rinse feed to full sheeting. | CI Sprinse Rinse Additive | Sheeting will not hold — verify final-rinse temperature and flow. |
| S4Sanitizer ppm reads low | Sanitize | Check drum level, pump calibration, eductor dilution, and strip freshness. | CI Sanitrol | ppm still short after calibration — confirm no hot-water dilution at the eductor. |
| S4Odour or aftertaste on beer and wine glass | Sanitize | Move the whole glass program to non-chlorinated wash and iodine. | CI Bar Glass CleanerCI Sanitrol | Odour persists — audit every product touching the glass line. |
| S5Foam in the wash tank | Verify | Confirm machine detergent only; rinse presoaked ware before racking. | CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoak | Foam persists after drain and refill — trace the manual chemistry source. |
| S5Rewash rate climbing | Verify | Read the four numbers before changing any product. | All four read in band — look at rack loading, scraping, and machine mechanics. | |
| S6Weak spray pattern or slow booster recovery | Maintain | Run a delime cycle and shorten the interval. | CI Scalzoff Acid Descaler | Recovery does not improve — escalate to equipment service. |
| S6Manual sink work | Maintain | Standardize one manual detergent for the sink line. | CI ZIP Pot & Pan DishWashCI Platinum Dish DetergentCI Soft & Gentle | Never dosed into a machine tank, under any circumstance. |
| Rule of thumb | If the answer to a warewash problem is “change the detergent,” check temperature, rinse feed, and the delime interval first. Most sites that are unhappy with their chemistry are running correct chemistry out of calibration. | |||
Set it right once, then hold the numbers
Commissioning turns the stage architecture into set-points any operator can hold.
Commission the machine with verified sanitizer ppm, detergent feed, rinse performance, and PM intervals, then document the set-points so results do not depend on who is on shift. A warewash program that lives in one supervisor’s head resets every time that person moves on.
Identify high-temp or low-temp operation and confirm one-pump versus two-pump rinse logic before any chemistry is connected. This decides the sanitize lane and the feed architecture.
Start at 2–4 mL/L through the dispenser, then verify low foam and first-pass cleanliness before adjusting the controller. Record the setting.
Set to full sheeting. Ware should exit with no standing droplets and no breaks in the film, drying in 8–15 seconds.
Confirm iodine or chlorine ppm with current test strips on low-temp and bar-glass systems. On bar glass, 0.7 mL/L to a 12 ppm target, with no hot-water dilution at the eductor.
Place the presoak at the scrape station with visible dilution, temperature band, and dwell-time instructions. Staging without instructions is not staging.
Set a recurring descale cycle based on measured local hardness rather than guesswork, and put it in the work-order system so it survives staff changes.
Iodine or chlorine reading at the final rinse, logged at least once per shift on low-temp and bar-glass machines.
High-temp 180–195 °F, low-temp around 160 °F, bar glass around 140 °F — read at the rack.
Confirm full sheeting. Adjust immediately if spotting or breaks in the film appear, and always after a delime cycle.
Conductivity control where available, timed feed where it is not. Log the set-point so drift is visible.
Racks needing a second pass. This is the number that summarises the whole program — investigate any upward movement.
Log every delime cycle and tie the interval back to measured water hardness rather than to what is visible on the arms.
| What the site reports | First move | Products | Why |
|---|---|---|---|
| APPEARANCE | |||
| “There is white film on glasses and plates.” | Raise rinse feed, then delime. | CI Sprinse Rinse AdditiveCI Scalzoff Acid Descaler | Film is hard-water residue. Rinse-aid acid strength for the local hardness and a missed delime interval cover most cases before chemistry changes. |
| “We delimed and it still spots.” | Re-set the rinse feed after the delime. | CI Sprinse Rinse Additive | Descaling changes the machine surface and often the effective feed rate. Spotting straight after a delime is a feed problem, not a failed descale. |
| “The glassware is cloudy.” | Reduce concentration or temperature; move to the glass lane. | CI Bar Glass CleanerCI Sprinse Rinse Additive | Cloudy glass comes from chlorine contact, etching, over-concentration, or excessive temperature. Etching does not reverse — catch it early. |
| SOIL & SANITIZING | |||
| “Food soil is still on the ware after the cycle.” | Clear screens and arms, then check feed. | CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoak | Under-dosing, poor mechanical action, and clogged jets look identical from the rack. Rule out the mechanical causes first, then add a presoak for protein-heavy loads. |
| “The sanitizer ppm is reading low.” | Check level, pump calibration, and strip freshness. | CI Sanitrol | Product level, pump drift, eductor dilution, and expired strips are the four causes. Verify all four before changing the sanitizer. |
| “The beer glasses smell and the heads fall flat.” | Take chlorine out of the glass program. | CI Bar Glass CleanerCI Sanitrol | Chlorine in wash or rinse is the cause. Non-chlorinated wash chemistry plus iodine at 12 ppm, with no hot-water dilution at the eductor. |
| FOAM & MANUAL LINE | |||
| “The wash tank is foaming.” | Confirm machine detergent only; rinse before racking. | CI Machine Dishwash L-TypeCI WareWash Enzyme PreSoak | Either a manual detergent has entered the tank or presoaked ware went in unrinsed. Drain, refill, and find the source rather than dosing around it. |
| “Which detergent for the pot sink?” | Standardize one manual product for the sink line. | CI ZIP Pot & Pan DishWashCI Platinum Dish DetergentCI Soft & Gentle | Cookware, high-volume sink work, and food-plant duty each have a fit. Pick one as the site standard and keep it out of machine dosing. |
| “What sanitizes the prep tables?” | Use the surface disinfectant, not the machine sanitizer. | CI OstroSan Quat | Food-contact surface sanitizing is a separate system from machine rinse sanitizing. The two products are not interchangeable in either direction. |
If the number is not on a log, the sanitize step is an assumption. This is the first thing an inspector asks and the last thing most sites can answer.
Parallel detergents mean nobody decided. Alkalinity stacks, glass etches, and results cannot be compared between shifts.
By then it is already restricting flow and insulating elements. Visible scale is a missed interval, not a schedule.
Temperature, ppm, sheeting, rewash rate. A dishroom holding these four can diagnose instead of guess.
The single figure that proves presoak, wash, rinse, and sanitize are working together. Track it and defend it.
Feed rates, dwell times, ppm targets, and the delime interval documented where the work happens. A documented program survives turnover.
CI360™ Warewash is a task-based program guide, not a substitute for site-specific procedures. Confirm dilution ratios, dwell times, temperatures, and sanitizer concentrations against current product labels, SDS, and the applicable local health authority requirement before use. Sanitizer concentrations and final-rinse temperatures are regulated values — verify them against your jurisdiction. Follow site SOPs, training, PPE, and applicable regulations. Never mix acid descaler with chlorinated or alkaline chemistry. Product names follow the Chem International catalogue; linked names open the product page on chemintonline.com.
Need a site-specific commissioning package?
CI360 can be translated into controller set-points and a wall-chart commissioning sheet with feed rates, ppm targets, temperature bands, and a delime interval matched to your machines, your controllers, and your water.
CI360™ · WW · 3 machine classes · 5 injection points · 27 products
A warewash program does not fail because the chemistry is weak. It fails because the final rinse never reached temperature, the sanitizer drifted, or the delime was skipped — and nobody measured any of it.
WarewashBuilt around the job, not the catalogue.
Section 01 · Where the chemistry actually goes
Five points. Five jobs. No overlap.
A warewash problem is almost always a point problem — the wrong chemistry at the right point, or the right chemistry at a point that is not being measured.
Presoak sink
Protein, tannin, silver and plastic staining — broken before the rack ever loads. Presoak is not one bucket for everything.
Prewash / scrap
Bulk soil removed mechanically. Rinse presoaked ware here so presoak residue never reaches the wash tank.
Wash tank detergent
Match the detergent to the machine before adjusting the dose. Under-dose shows as soil left on ware; the wrong detergent shows as foam.
Final rinse injector
Rinse additive sheets the water so heat can do the drying. On a low-temp or bar-glass machine this point also carries the sanitizer. Temperature is verified first, always.
Dry / stack
No chemistry. If ware is wet or spotted here, the fault is upstream at point 4 or in the delime interval — not a drying problem.
The section is the navigation. Callout circles are anchors — clicking 3 jumps to the wash-tank module. On a phone the drawing scrolls and the numbered key below carries the same five points in the same order, so the printed sheet and the screen always agree.
Section 02 · What has to hold
Four numbers decide whether the program is working.
A clean-looking rack does not prove the machine is operating correctly. Nothing below this panel matters if these four are out of band.
Verified at the rack, not at the gauge on the door. Ticks mark the other two machine classes: bar glass around 140°F, low-temp around 160°F / 71°C — both of which require a verified chemical sanitizer instead.
Auto-feed setting for J430 and J440, adjusted to soil load and water hardness. Confirm low foam and first-pass cleanliness before moving the controller.
CI Sanitrol calibrated to 12 ppm at the final rinse. Do not dilute iodine with hot water at the eductor — it strips the residual you just paid for.
J565 at 1:20 with at least ten minutes of dwell. Too cold slows enzyme activity; above roughly 50°C the protease denatures and the bath is doing nothing.
Every band on this panel is published, not estimated. Where a value depends on the site — water hardness, soil load, controller type — the page gives the method and the frequency instead of a number. Nothing here gets a figure it cannot defend.
Section 03 · One module per point
Start with the rinse temperature. Chemistry second.
The program starts with one question: what final-rinse temperature is the machine actually delivering? That answer decides detergent choice, rinse logic, sanitizer requirement, and the PM schedule that keeps the machine out of film, spotting, rewashes, and failed sanitization.
Presoak sink · before the rack
Presoak is not one bucket for everything. Protein, tannin, silver, plastic staining and mixed soil each need their own lane, so the machine is not forced to solve every problem alone. Rinse presoaked ware before racking or the residue foams the wash tank.
Main-wash aggression gets raised to compensate for soil that should have been released in the sink. Flatware still comes back with protein, plastics still stain, and the detergent cost climbs while first-pass results get worse.
Prewash / scrap · no chemistry
Bulk soil comes off mechanically here. This point exists on the sheet precisely because nothing should be dosed into it — and because it is where presoaked ware gets rinsed before racking. Screens, jets and wash arms clear at this point are worth more than any dose change downstream.
Excessive foaming in the wash tank, traced back to unrinsed presoak residue or a manual detergent that was never meant to enter the machine. Drain and refill if the foam persists.
Wash tank detergent · match the machine first
Three machine classes, three detergent lanes. The lane is decided by the machine's temperature profile and its sanitizing method — not by soil load, and not by preference. Dose 2–4 mL/L by auto-feed and adjust to soil and water hardness only after the lane is right.
High-temp machines sanitize thermally. Low-temp machines require a verified chemical sanitizer. Bar glass needs non-chlorinated wash chemistry and tightly controlled iodine ppm. Chlorine in a glass program drives odour, film and spotting — it is not a dose problem, it is the wrong lane.
Final rinse injector · sheeting, then sanitizing
Two jobs share one point. Rinse additive sheets the water so heat can dry the ware; on any machine that does not reach 180°F, this point also carries the sanitizer. Where the machine has two rinse pumps, keep rinse aid and sanitizer separate. Where it has one, use combined feed only if the controller and the product were designed for it.
Sanitizer ppm below the threshold is a stop-work condition, not a note for the next shift. Check product level, pump calibration and eductor dilution, and re-test with a fresh strip from the current lot before changing anything else.
Dry / stack · no chemistry
Nothing is dosed here, and nothing should be corrected here. Wet ware is a point-4 fault — rinse-additive feed or final-rinse temperature. Spotted ware is a hardness and delime fault. Towel drying hides both and re-contaminates sanitized ware.
An operator who reaches for a towel instead of the rinse-aid setting. The symptom stops appearing and the underlying drift keeps running until the descale interval is missed too.
Off-point · machine PM and everything outside the machine
Two lanes that belong to the warewash program but do not sit on the drawing. Deliming is scheduled maintenance, not a detergent. Manual sink chemistry is a separate system and never enters the machine.
Warewash systems fail when a site piles on overlapping detergents, mixed rinse chemistry and a random sanitizer choice. Every product above answers to one point and one job. If two products are doing the same job on the same pass, one of them is the problem.
Section 04 · Out of band
Most warewash failures are drift, not chemistry.
Film, spotting, rewashes and failed sanitization are usually a feed problem, a temperature problem, or a PM problem. Work the ladder in order — changing the product first is the most expensive way to find that out.
The correction ladder · run it on every control target, in this order
Prove the reading
Re-test with a fresh strip from the current lot, or a calibrated thermometer at the rack. Half of all "chemical failures" are measurement failures.
Check the machine first
Pump calibration, eductor dilution, product level, screens, wash arms, booster temperature. Chemistry cannot fix a pump that is not pulling.
Correct the dose
One change at a time, back to the labelled setting. Record the reading before and after — not just the controller setting.
Change the chemistry
Only now. If the machine class, water condition or soil load has genuinely changed, move lanes — do not stack a second product on top of the first.
Field translation · observed condition to corrective action
Most spotting and film traces back to two things before anything else: insufficient rinse-aid acid strength for local hardness, or a missed descale cycle. Fix those before changing detergent chemistry.
Section 05 · Ready-to-deploy site logic
Three machine classes. Pick the one you actually run.
The difference between these columns is not quality. It is what the machine is physically able to do — and therefore what has to be measured to prove it is working.
DEFAULT ROUTE
The rows never change. Site signature, then the points in drawing order, then PM, then swap-if. Every CI360 application publishes the same seven rows with different columns, so a reader who has read one page can read all five.
Section 06 · Build the stack
Answer three questions. Leave with a stack you can order.
Everything above this point is reasoning. This is where it resolves into a named product at every point, with the dose and the control target attached — the same sheet a rep would write on your counter.
The stack builder does not price anything. It returns products, points, doses and control targets — the specification. Pack sizes and price are set against your water report and volumes when the request comes through.
Section 07 · The kit
Program A · high-temperature site kit
Nothing in this kit does the same job twice — which is the entire reason it is published as a kit instead of a category.
Have this kit reviewed against your water report, your machine's verified final-rinse temperature, and your controller before you order. Program B and C kits substitute at points 3 and 4 only.
Request this kit →No pricing on this page. The kit carries products, points, doses and control targets. Pack sizes and price stay behind the quote request, as they do everywhere else on the site.
Section 08 · Commissioning and control
Set it right once, then lock the set-points down.
Commission the machine with verified ppm, mL/L and temperature targets, then document the set-points so any operator on any shift can hold them without guesswork.
Verification schedule · what is measured, how, and how often
This is the whole program. Chemistry that is not measured is not a program — it is inventory. The verification schedule above is what turns the products on this page into a result the site can defend to an inspector.
CI360™ · WW · Warewash
Start with actual rinse temperature. Everything else follows from it.
Match the detergent to the machine, the rinse aid to the water, and the sanitizer to the application. Verify ppm, verify sheeting, and delime on schedule. Most warewash failures come from drift, not from a lack of chemistry.
Chem International can translate this sheet into controller set-points and a commissioning checklist matched to your exact machines, controllers and water report.